GreenArrow Email Software Documentation

Event History

GreenArrow CloudMTA

This feature is only available on GreenArrow CloudMTA. On other installations, the page is not in the menu.

Overview

The Event History page lists the events that GreenArrow stores for its statistics: delivery attempts, bounces, spam complaints, clicks, opens, unsubscribes and more. It shows them newest first, 100 on each page. Filters above the list choose the time range, the event types, the recipient, the RFC5321.MailFrom domain, the click tracking ID, the IP address or relay server, and the throttle. You can download every matching event as a CSV or JSON Lines file.

To open the page, click “Event History” in the “Statistics” section of the GreenArrow Engine web interface.

Users whose UI permission is full access or read-only can use the page. Users with stats-only permission cannot.

The page reads its events from the Events API, which gives the same events and filters to your own programs.

Filters

The page shows the events that match every filter that is set. You can change the filters while the page loads events. When you change a filter, the page stops the current load and loads the first page again.

Time Range

Click the Time Range box to open the time range picker. Click a quick range, such as Last hour, Last 7 days or Yesterday, to show it at once. Or type a range in the From and To boxes, and click Apply (or press Enter). Each box takes:

  • a time, such as 2026-11-06 07:00 or 2026-11-06 07:00:30, in the engine_time_zone, which the Time Range label shows.
  • a time before now: now- and a number of minutes (m), hours (h), days (d) or weeks (w), such as now-30m, now-6h, now-2d or now-1w. Add /d to go back to the start of that day: now/d is the start of today, and now-1d/d is the start of yesterday.
  • nothing. With no From time, the range is the 24 hours before the To time. With no To time (or now), the range ends now.

The page shows the last 24 hours when no range is chosen.

A range of times before now stays relative: the page’s URL keeps now-6h, so a reload or a shared link shows the 6 hours before that moment. The page works out the times when it loads the events, and Load more events uses the same times.

There is no limit on the length of the time range, but a long range with filters that match few events can take longer than the time limit (see When a Search Takes Too Long).

Recipient

An email address, such as [email protected], shows the events of that address. A domain, such as example.com, shows the events of every address at that domain, but not at its subdomains. The filter matches whole values only, and it ignores case.

MailFrom Domain

The domain of the RFC5321.MailFrom address, such as example.com. It matches whole domains only, and it ignores case.

Click Tracking ID

The click tracking ID of the message, as set with the X-GreenArrow-Click-Tracking-ID header. It matches the whole ID exactly, and case matters. The events of one message share its click tracking ID: its new_message, delivery_attempt, bounce_all, bounce_bad_address and scomp events, and its engine_click, engine_open and engine_unsub events.

Outgoing VirtualMTA

The IP address or relay server that sent the message. Click the box to choose from the list, or type to search the names. The list groups the IP Addresses and the Relay Servers, and shows the address of each IP address, as in pool-a (192.0.2.10). It does not have routing rules, because an event names only the IP address or relay server.

Remote Throttle

A domain of the throttling rules. The list has each domain of the throttles once; type to search it. Each IP address has its own throttle for each rule, so a domain shows the events of the throttles of every IP address that have it. With an Outgoing VirtualMTA chosen too, it shows the events of that IP address’s throttle only.

With no event types chosen, choosing an Outgoing VirtualMTA or a Remote Throttle limits the events to delivery_attempt events, and the ? icon of each box says so. The two boxes are shown only to users who can view the VirtualMTAs section of the web interface. For other users, a VirtualMTA or throttle filter in the page’s link (see Links and the Back Button) still applies. The page shows it as text with a × button that removes it.

Event Types

Choose the event types to show. Type to search the list, and click the × of a chosen event type to remove it. With none chosen (All event types), the page shows every event type that the other filters can match. An Outgoing VirtualMTA or a Remote Throttle limits this to delivery_attempt events (see above).

Some event types do not store every value, so some filters can never match them. You can still choose those event types: they show no events. For example, a bounce_lite event stores no recipient, so with the Recipient filter set it shows no events. See Filters and Event Types for the full list.

The Recipient, MailFrom Domain and Click Tracking ID boxes, and the event types, apply half a second after your last change. A quick range, and the Outgoing VirtualMTA and Remote Throttle boxes, apply at once. A typed time range applies when you click Apply.

Clear all

The Clear all button at the top of the filters clears every filter at once. The time range goes back to the last 24 hours. The back button shows the filters again.

The List of Events

Each row shows the time of the event, its type, the recipient’s email address, a summary of the event, and a View button. Event Summaries describes the summary of each event type.

The page shows the newest 100 events first. When more events match, click Load more events to add the next 100 under them. When no more events match, the page says “All matching events are shown above.” If loading more fails, the events stay on the page, and you can click the button again.

GreenArrow stores the time of an event to the second. Events in the same second can be in any order.

View

The View button shows the values that GreenArrow stores for the event’s type, and the values that the Events API adds (summary, and email and throttle for the event types that have them). A value of the event type that is not set shows as null. Long values, such as the message headers and the bounce text, scroll in their own box. A value that holds JSON, such as headers or smtp_timing, is shown with one item on each line.

A value that the page can filter by has a filter icon at the end of its row. Click the icon to show the events with that value, in the same time range. The other filters are cleared.

Value Filter
event_type Event Types
email and email_localpart Recipient, with the recipient’s address
email_domain Recipient, with the recipient’s domain
sender MailFrom Domain, with the sender’s domain
click_tracking_id Click Tracking ID
outmtaid and outmtaid_name Outgoing VirtualMTA
throttleid Remote Throttle

The outmtaid, outmtaid_name and throttleid rows have a filter icon only for users who can view the VirtualMTAs section of the web interface.

Close it with the Close button, the close icon, or the Escape key.

Downloading Events

The Download CSV and Download JSON buttons above the list download every event that matches the filters, not only the events on the page. The file uses the time range of the events on the page. With no To time, the file ends at the time of the download, so it can have events that are newer than the list.

GreenArrow sends the file while it reads the events, so a large file starts at once. The file is named events. and the date, such as events.2026-11-06.csv.

CSV

The first line has the names of the columns. The file has a column for each value of every event type, and for the email, summary and throttle values that the Events API adds. Every file has the same columns, whatever the filters. A value that an event’s type does not have is empty. The throttle column has the throttle’s name.

JSON Lines

The Download JSON button gives a JSON Lines file, such as events.2026-11-06.jsonl: each line is a JSON object for one event, with no array around them. Each event has the values that the View button shows.

When a Download Fails

Each file reads the events in pages of 500, and each page has the 30-second time limit of a search (see When a Search Takes Too Long). When the first page takes too long, the browser shows the error instead of a file. When a later page takes too long, the file stops, and its last line says “The export stopped before its end:” and the reason. In a JSON Lines file, that line is not JSON.

The page keeps its filters in its URL. You can copy the URL to show the same events to another user, and the back button returns to the filters before. After a reload, a link or the back button, the page shows the newest events again, without the events that Load more events added.

A link can also name a VirtualMTA by its name (outmta_name), or one throttle by its ID (throttle_id), as the Events API does. The Outgoing VirtualMTA and Remote Throttle boxes show these, and an option that you choose replaces them. An IP address, relay server or throttle in a link that no longer exists is marked as deleted.

When a Search Takes Too Long

The page stops a search that takes longer than 30 seconds, and asks you to use a shorter time range or change the filters. The search reads the events of one filter, and tests the other filters on each event that it reads. So a long time range, with filters that rarely match together, can take too long.

After an upgrade to a version with the Event History page, GreenArrow builds the indexes that the filters use, in the background. It builds the newest days first. On an installation with many stored events, this can take hours, and until it is done, a filtered search on older days can take too long.


Copyright © 2012–2026 GreenArrow Email